RoofingNorthern Beaches

How many downpipes does your roof need?

Enter a gutter run, the distance to the ridge and the roof pitch. See the roof area it drains, how many downpipes the building code’s Housing Provisions call for at Sydney rainfall, which eaves gutters suit, and the overflow it needs.

  • NCC Housing Provisions Part 7.4 tables
  • Sydney and Avalon rainfall
  • Checked 6 October 2026

Send an enquiry

Gutter and downpipe sizing, Northern Beaches: heavy rain running off a tile roof into a quad gutter and metal downpipe

Gum leaves aren’t the only reason gutters overflow. The building code’s own notes say “Insufficient and poorly located downpipes are a frequent cause of poor roof drainage system performance.” Its Housing Provisions set a simple sizing method for eaves gutters on houses, and this calculator runs it for one gutter run at a time, with the arithmetic shown.

Gutter and downpipe calculator

Do one eaves gutter run at a time: each side of the roof that drains into one gutter.

Rainfall figure
metres

metres

Measure level, as on a site plan, from the gutter to below the ridge (or the top of a skillion), not up the roof. Up to 100 m of gutter and 30 m to the ridge.

Your house plans or the roofer can tell you.

Your result

Enter a gutter run above. The Housing Provisions tables it uses are below.

How the gutter and downpipe calculator works

  1. Roof area. The Australian Building Codes Board’s guide multiplies the gutter length by the distance from the gutter to the ridge. A pitched roof catches more rain than its plan area, so we add Lysaght’s published allowance for pitch: “As a ‘rule of thumb’ allow 1% for every degree of pitch up to 36°”. Lysaght refers to AS/NZS 3500.3 for the exact increase. Above 36° we hold it at 36%, and a roof plumber should work it out from AS/NZS 3500.3.
  2. Downpipes by length. Each downpipe must “not serve more than 12 m of gutter length”.
  3. Downpipes by area. The area each downpipe drains, and the rainfall, set the eaves gutter types Table 7.4.3a accepts. If none of the usual gutters fits, the calculator adds a downpipe and checks again.
  4. Overflow. Tables 7.4.4a and 7.4.4b set how much a blocked gutter must be able to spill away from the house in the heavier 1% rainfall. Table 7.4.4a’s ridge-to-gutter length uses the plan distance.

The Housing Provisions method has its own limits. Under H2D6(3) of the building code, Part 7.4 “may only be used provided the roof drainage system is connected to a stormwater drainage system that complies with H2D2” and “excludes box gutters”.

Some readings are ours. The pitch allowance is Lysaght’s rule of thumb, not the code’s. Table 7.4.3a has no row for 201 or 210 mm/h, so we use the next row up (225 mm/h); and a roof area between two columns uses the next column up. The code allows interpolation only for the overflow tables, which we interpolate. A licensed roof plumber or the certifier has the final say.

Sydney and Avalon rainfall for gutters

Table 7.4.3d 5 minute duration rainfall intensities (Sydney rows)

2 rows
StateLocalityAnnual exceedance probability, 5% (mm/h)Annual exceedance probability, 1% (mm/h)
NSWSydney201262
NSWAvalon, Sydney210287

ABCB Housing Provisions Standard (NCC 2022), Table 7.4.3d, the two rows relevant to the Northern Beaches, reproduced verbatim and checked 6 October 2026. The table note says its locations “are based on the nearest Bureau of Meteorology grid cell latitude and longitude to the central Post Office of each city or town.” The 5% figure sizes the gutter; the 1% figure sizes the overflow.

Eaves gutter sizes by roof area per downpipe

Table 7.4.3b Gutter sizes for various rainfall intensities

6 rows
Gutter typeGutter descriptionMinimum cross-sectional area (mm²)
AMedium rectangular gutter6500
BLarge rectangular gutter7900
C115 mm D gutter5200
D125 mm D gutter6300
E150 mm D gutter9000
FGutter must be designed in accordance with AS/NZS 3500.3N/A

ABCB Housing Provisions Standard (NCC 2022), Table 7.4.3b, reproduced verbatim and checked 6 October 2026. The area is “measured up to the lowest part of the relevant overflow facility”.

Table 7.4.3a Size of gutter required to drain roof catchment area into one (1) downpipe for various rainfall intensities and roof catchment areas (A, B, C, D, E and F defined in Table 7.4.3b)

11 rows
Design rainfall intensity (mm/h) (as per Table 7.4.3d)Roof catchment area per downpipe — 30 m²Roof catchment area per downpipe — 40 m²Roof catchment area per downpipe — 50 m²Roof catchment area per downpipe — 60 m²Roof catchment area per downpipe — 70 m²
90 mm/hA or CA or CA or CA or CA or C
120 mm/hA or CA or CA or CA or CA or D
140 mm/hA or CA or CA or CA or DB or E
160 mm/hA or CA or CA or CA or EB or E
175 mm/hA or CA or CA or DB or EE
200 mm/hA or CA or CA or DB or EF
225 mm/hA or CA or CA or BEF
255 mm/hA or CA or DB or EEF
275 mm/hA or CA or DB or EFF
325 mm/hA or CB or EFFF
425 mm/hA or CEFFF

ABCB Housing Provisions Standard (NCC 2022), Table 7.4.3a, reproduced verbatim and checked 6 October 2026. Letters are the gutter types above; F means the gutter “must be designed in accordance with AS/NZS 3500.3”. Table 7.4.3c accepts every listed downpipe (75 mm and 90 mm round, 100 × 50 mm and 100 × 75 mm) with every gutter type, except a 75 mm round downpipe with a type E 150 mm D gutter.

Gutter overflow: slots, back gaps and rainheads

Eaves gutters must also be “fitted with overflow measures capable of removing the overflow volume” in Tables 7.4.4a and 7.4.4b, sized for the 1% rainfall. These are the measures the Housing Provisions accept and what each can remove:

Overflow measures in 7.4.6 and 7.4.7 (summary)

7 rows
MeasureTypeOverflow capacity
Front face slotted gutterContinuous, along the gutter0.5 L/s per metre
Controlled back gapContinuous, along the gutter1.5 L/s per metre
Controlled front bead heightContinuous, along the gutter1.5 L/s per metre
End-stop weirDedicated, at one point0.5 L/s
Front face weirDedicated, at one point1 L/s
Inverted nozzleDedicated, at one point1.2 L/s
RainheadDedicated, at one point3.5 L/s

Our summary of the ABCB Housing Provisions Standard (NCC 2022), 7.4.6 and 7.4.7, checked 6 October 2026; not a copy of the clauses. Each comes with installation conditions, such as slots or weirs set at least 25 mm below the top of the fascia. An end-stop weir isn’t suitable where the end stop abuts a wall.

Other gutter rules worth knowing

  • Eaves gutters must be “installed with a fall of not less than 1:500” and “supported by brackets securely fixed at stop ends, corners and at not more than 1.2 m centres”.
  • Valley gutters must be “installed on a roof with a pitch more than 12.5 degrees” and “have minimum freeboard of not less than 15 mm”.
  • Gutters, downpipes and flashings must “not contain any lead if used on a roof forming part of a drinking water catchment area”, which matters with a rainwater tank.
  • Box gutters aren’t covered by Part 7.4: the code points to AS/NZS 3500.3.

Near the coast, the steel matters too: BlueScope’s gutter bulletin lists standard Colorbond and Zincalume rainwater goods more than 200 m from salt marine influence and Colorbond Ultra more than 100 m. The coastal roof material finder applies it to your distance. On bush fire prone land, see the BAL roofing requirements. For repairs, replacement and gutter guard, see gutters, downpipes and gutter guard.

Who can install gutters and downpipes

In NSW, gutter and downpipe work is roof plumbing, and work over $5,000 including GST needs a contractor licence in the right category. Check the licence on the Service NSW licence register.

Common questions

Is a 115 mm quad gutter big enough?

In the 225 mm/h row this calculator uses for Sydney and Avalon, Table 7.4.3a lists type C, the 115 mm D (quad) gutter, for up to 40 m² of roof per downpipe. Beyond that the table lists other gutter types, and at 70 m² per downpipe it calls for a gutter designed to AS/NZS 3500.3.

Do gutters need overflow slots?

Under the Housing Provisions, eaves gutters must be fitted with overflow measures for the 1% rainfall, such as front face slots, a controlled back gap or a rainhead, so that a blocked gutter overflows away from the house. Gutters fixed to a verandah or an eave more than 450 mm wide are excepted where it has no lining, or is raked with a lining sloping away from the building.

Extracts from the ABCB Housing Provisions Standard (NCC 2022) are reproduced verbatim: © Commonwealth of Australia and the States and Territories 2022, published by the Australian Building Codes Board (CC BY-ND 4.0). The same tables appear in NCC 2025, which was provided by the Australian Building Codes Board under the CC BY 4.0 licence. The overflow measures table is our summary, and the calculator’s arithmetic and readings are ours.

Where this information comes from

The rules in this tool on this page come from these published pages, checked on 6 October 2026.

Gutters overflowing in heavy rain?

Describe the job, what the roof is made of and your suburb. Include the number of storeys and any access issues.

Roofing quote, Northern Beaches: roofer in a harness fitting a skylight into a dark concrete tile roof